Take a look at the pictures and think about getting water on the fire to the upper floor and/or making rescues. This building is one that is old and not sprinklered. It sits off of the road and aerial access is extremely limited, almost ineffective.

no images were found

When looking at this type of building we need to consider the construction type, occupancy, access and egress points and any special hazards. What are our initial resources and what should we have coming on the way? This building is four stories and is a dormartory at a college. The corridor length is 225 from stairwell to stairwell. As you look at the building in the picture, the stairwell on the right is more remote from a parking surface than the one on the left. The elevation that you see in the picture from this side is the same on the opposite side.

There is a basement under this building with tunnels that lead to other campus buildings with limited access and egress where kids sneak away to do what kids sneak away to do. There is a great deal of combustible storage in these basements and tunnels.

Type 3 construction is the type of building we are dealing with and the interior has been altered over the years. There is an automatic alarm system but no standpipes. Water supply is limited; the closest hydrant is approximately 300 feet from where you would likely place first in companies and that hydrant, if laid from, would severely hinder access by other units because of only one access to the campus.

So, here we go……..what are your tactics and why? Watch the video and let everyone know what you would do and why. Use this for discussion purposes and relate it to buildings that you might have in your jurisdiction. Share your thoughts and ideas.

Train hard and we hope to see most of you at FDIC 2012 next week.

<p
</p

 

 

Leave a Reply

Your email address will not be published. Required fields are marked *

background image Blogger Img

Jason Hoevelmann

Deputy Chief/Fire Marshal with the Sullivan Fire Protection District, a combination department, and a career firefighter/paramedic with the Florissant Valley Fire Protection District in North St. Louis County.

FE Talk: Humpday Hangout

Comments
Dan Martin
Choosing the Right Bailout Kit
There is academic research out there on portions of these systems; specifically the ropes. Feel free to contact the University of Illinois Fire Service Institute, Firefighter Life Safety Research Institute to get more information. We all are in this together, to keep firefighters safe.
2015-02-12 21:42:32
reny
5 Week Officer Development Program: Online
Do you get a cert like fire officer 1 or 2 when your done?
2015-02-11 01:19:17
Jeff Coffey
5 Week Officer Development Program: Online
What is the cost of this online course?
2015-02-10 19:41:17
Evan
5 Week Officer Development Program: Online
will you get a certification or a certificate?? Is it at ur own speed?
2015-02-10 19:39:42
Omar
The 2 1/2″ Line: Sweat, Effort and Persistence
Nosotros usamos el 2 1/2 como respaldo principalmente en estructuras grandes como edificios, para casas solo usamos de 1 3/4, los tendidos de respaldo en 2 1/2 andan pre conectados en la parte posterior del camión y tenemos las líneas de alimentación en 3 pulgadas que usamos también para extender los tendidos, en si, las…
2015-02-07 21:15:02

Jason Hoevelmann's Discussions

/* Removes Buzzboost Logo (MBT) */ div #creditfooter{ display: none; }
Follow Jason Hoevelmann

AFFOWE Calandar

April 2012
M T W T F S S
« Mar   May »
 1
2345678
9101112131415
16171819202122
23242526272829
30  

FireEMS Blogs eNewsletter

Sign-up to receive our free monthly eNewsletter

LATEST FIREFIGHTER NEWS

HOT FORUM DISCUSSIONS

LATEST ON FIRE ENGINEERING

FEATURED DISCUSSIONS